Periodic Maintenance Schedule
| Item | Location | Daily | Weekly | Monthly | Quarterly | 
| Contact Tip | Torch | ✅ | 
 | 
 | 
 | 
| Air Filters | Robot Cabinet | 
 | ✅ | 
 | 
 | 
| Nozzle | Torch | 
 | ✅ | 
 | 
 | 
| Retaining Head | Torch | 
 | 
 | ✅ | 
 | 
| Liner | Torch | 
 | 
 | ✅ | 
 | 
| Drive Rolls | Feeder | 
 | 
 | 
 | ✅ | 
- Change nozzle if spatter does not readily come off 
- Change the retaining head if the gas ports become clogged 
- Change the liner if the wire does not feed smoothly 
- Change the drive rolls if slippage is noticed 
Robot Controller Air Filter Maintenance
The robot controller contains two air filters, one located on each side of the control cabinet.
- Gently remove the outer plastic frame, by pulling where the red arrows are shown. The frame will tilt out. 
- Remove the filter to clean it. Clean using low-pressure air or replace filters if necessary. Remember to clean each side. 